Q51. In induction type energy meter, the disc rotates due to
A) Interaction of magnetic fields
B) Electric field
C) Heat
D) Friction
Answer: A
Q52. The phase angle error in induction meter occurs due to
A) Lagging current in voltage coil
B) Lagging current in current coil
C) Eddy currents
D) Both A & B
Answer: D
Q53. The primary standard of resistance is
A) Wire-wound resistor
B) Carbon resistor
C) Potentiometer
D) Metal oxide resistor
Answer: A
Q54. The AC potentiometer differs from DC potentiometer by
A) Use of phase-shifting device
B) Use of AC supply
C) Use of moving coil
D) None
Answer: A
Q55. In a Schering bridge, the unknown is
A) Capacitance and dielectric loss
B) Resistance
C) Inductance
D) Power
Answer: A
Q56. A Wien bridge can measure frequency accurately because
A) Bridge balance is independent of source voltage
B) Very high resistance
C) Low power loss
D) None
Answer: A
Q57. The main advantage of a DSO over analog CRO is
A) Can store and analyze transient waveforms
B) High accuracy
C) Low cost
D) Less maintenance
Answer: A
Q58. The sampling frequency of digital instruments must satisfy
A) Nyquist criterion
B) Half the signal frequency
C) Any value
D) Zero
Answer: A
Q59. The main error in digital voltmeters is due to
A) Quantization
B) Loading
C) Temperature
D) Phase
Answer: A
Q60. A dual-slope ADC is preferred due to
A) Noise rejection
B) High speed
C) Low resolution
D) High cost
Answer: A
Q61. The integrating type ADC is immune to
A) High frequency noise
B) Temperature
C) Supply voltage variation
D) All of the above
Answer: D
Q62. The resolution of a 12-bit ADC is
A) 1/4096 of full scale
B) 1/1024
C) 1/2048
D) 1/8192
Answer: A
Q63. In a digital multimeter, the reference voltage should be
A) Highly stable
B) AC voltage
C) Low current
D) Variable
Answer: A
Q64. The main advantage of PMMC instruments is
A) High accuracy and linear scale
B) Can measure AC directly
C) Low cost
D) Robustness
Answer: A
Q65. The main limitation of MI instruments is
A) Non-linear scale
B) Sensitive to polarity
C) Only AC measurement
D) Cannot measure current
Answer: A
Q66. In moving iron instruments, hysteresis effect occurs due to
A) Magnetic material of core
B) Coil resistance
C) Eddy currents
D) Spring stiffness
Answer: A
Q67. The sensitivity of voltmeter is expressed in
A) Ω/V
B) V/Ω
C) Ampere
D) Volt
Answer: A
Q68. The sensitivity of ammeter is expressed in
A) A/Ω
B) Ω/A
C) Volt
D) Ohm
Answer: B
Q69. A dynamometer type instrument can measure
A) Both AC and DC
B) AC only
C) DC only
D) None
Answer: A
Q70. The main advantage of dynamometer type instrument is
A) Can measure power in AC circuits with any power factor
B) High speed
C) Low cost
D) None
Answer: A
Q71. The maximum current that can safely flow through an ammeter is determined by
A) Full scale deflection current
B) Shunt resistance
C) Coil resistance
D) All of the above
Answer: D
Q72. The term “burden” in CT refers to
A) Load connected across secondary
B) Current rating
C) Voltage rating
D) All of the above
Answer: A
Q73. The accuracy of a CT decreases with
A) Increasing burden
B) Reducing burden
C) Constant burden
D) None
Answer: A
Q74. In a PT, phase angle error is mainly due to
A) Magnetizing current
B) Load current
C) Both
D) None
Answer: A
Q75. The main limitation of PMMC instruments for AC is
A) Cannot measure AC directly
B) Low accuracy
C) Non-linear scale
D) Fragile
Answer: A
Q76. A thermocouple converts
A) Temperature difference to voltage
B) Voltage to current
C) Current to displacement
D) None
Answer: A
Q77. The sensitivity of thermocouple increases with
A) Number of junctions (thermopile)
B) Length of wire
C) Temperature coefficient
D) All of the above
Answer: D
Q78. The RTD works on the principle of
A) Resistance changes with temperature
B) Capacitance
C) Inductance
D) Voltage
Answer: A
Q79. The PT100 sensor has resistance of
A) 100 Ω at 0°C
B) 100 Ω at 25°C
C) 110 Ω at 0°C
D) 200 Ω at 0°C
Answer: A
Q80. LVDT has
A) Infinite input impedance
B) Low input impedance
C) High current
D) Variable resistance
Answer: A
Q81. The output of LVDT is
A) AC voltage
B) DC voltage
C) Current
D) Frequency
Answer: A
Q82. Hall-effect sensor is used to measure
A) Magnetic field
B) Current
C) Voltage
D) Pressure
Answer: A
Q83. Piezoelectric transducer output is proportional to
A) Force or pressure applied
B) Voltage applied
C) Resistance
D) Current
Answer: A
Q84. A strain gauge output depends on
A) Mechanical strain
B) Voltage
C) Current
D) Temperature only
Answer: A
Q85. The gauge factor of strain gauge is typically
A) 2
B) 1
C) 10
D) 0.5
Answer: A
Q86. A frequency counter measures
A) Number of pulses per second
B) Voltage
C) Current
D) Resistance
Answer: A
Q87. The resolution of frequency counter improves with
A) Increasing gate time
B) Reducing input voltage
C) Increasing resistance
D) Decreasing capacitance
Answer: A
Q88. A function generator can produce
A) Sine, square, triangular waves
B) Only sine wave
C) Only square wave
D) Only triangular wave
Answer: A
Q89. The main advantage of digital instruments is
A) High accuracy, low loading, data storage
B) Low cost
C) Low speed
D) Analog display
Answer: A
Q90. The voltmeter loading error is reduced by
A) High input impedance
B) Low resistance
C) Series resistor
D) Parallel resistor
Answer: A
Q91. The peak value of a sine wave is
A) 1.414 × RMS value
B) RMS value
C) Average value
D) None
Answer: A
Q92. The average value of a sine wave is
A) 0.637 × peak value
B) RMS value
C) Peak value
D) 1.414 × RMS
Answer: A
Q93. A digital oscilloscope uses
A) ADC to convert input waveform
B) DAC
C) Both
D) None
Answer: A
Q94. The main source of error in AC measurement by PMMC with rectifier is
A) Harmonics
B) Temperature
C) Humidity
D) Parallax
Answer: A
Q95. Hot-wire instrument measures
A) True RMS value
B) Average value
C) Peak value
D) DC only
Answer: A
Q96. The shunt resistor in ammeter should have
A) Low resistance
B) High resistance
C) Medium resistance
D) Variable resistance
Answer: A
Q97. The multiplier in voltmeter should have
A) High resistance
B) Low resistance
C) Medium resistance
D) Variable resistance
Answer: A
Q98. The energy meter calibration is done using
A) Standard supply and reference meter
B) Multimeter
C) CRO
D) Wattmeter
Answer: A
Q99. Creeping in energy meter occurs due to
A) Friction and residual magnetism
B) Overload
C) Phase error
D) Load variation
Answer: A
Q100. The main advantage of induction type energy meter is
A) Accurate measurement of AC energy
B) Can measure DC
C) Low cost
D) Measures current only
Answer: A